Umthengi: Senegal — indawo eza kuqinisekiswa (eDakar / ummandla) Isihloko: impendulo kuluhlu lwezixhobo eziza kusetyenziswa Umhla: 22 Septemba 2026 — Inguqulelo 1.0
Uluhlu lwezixhobo zakho luguqulwe lwaba ngumthwalo wombane wokwenyani, emva koko lwalinganiswa noluhlu lweemveliso zethu. Nasi isigqibo:
Ulungelelwaniso olucetyiswayo: 1 × EP12000L (11 kW i-single-phase) + 1 × EP12000B ibhetri yolwandiso, ene-≈ 4.6 kW yeephaneli zelanga.
Kutheni le nto kukho olu qwalaselo, hayi olunye:
Isithintelo sokufakelwa kwakho | Ixabiso elibaliweyo | Ubuchule be-EP12000L | Umda |
Umthwalo oqhubekayo, zonke izixhobo zisebenza ngaxeshanye | 4.2 kW | 11 kW (230 V inqanaba elinye) | 2.6 × |
Ukuqalisa ngamandla (ukuqala kwepompo yomthombo + iketile + ukupholisa) | ≈ 7.5 – 9 kW | Incopho ye-22 kW | 2.4 – 2.9 × |
Uqikelelo lokusetyenziswa kwemihla ngemihla | ≈ 15.9 kWh/ngosuku | 7,680 Wh (EP12000L) + 11,776 Wh (EP12000B) = 19,456 Wh | ≈ usuku olunye olupheleleyo lokuzimela, kunye nokutshaja kwakhona kwelanga ngaxeshanye |
Eyona nto ibalulekileyo xa ufaka ayikokusebenza kwamandla, kodwa kukushukuma kwepompo yomthombo : injini yombane itsala amandla ayo aphindwe kathathu ukuya kane ngexesha lomzuzwana emva kokuba iqalile. Ijenereyitha ye-5 kW engabizi kakhulu iyama kuloo kushukuma; i-EP12000L iyifunxa ngokulula ngenxa ye-inverter yayo ye-sine wave ecocekileyo (THD < 3%).
# | Izixhobo | Ubungakanani | Amandla eyunithi (uqikelelo) | Amandla apheleleyo aqhubekayo | Ukwanda kwabasebenzi abaqalayo |
1 | Iibhalbhu ze-LED ze-12 W | 10 | 12 W | 120 W | — |
2 | IiTV zesikrini esisicaba ezingama-40" | 2 | 75 W | 150 W | — |
3 | Iifeni (ezimiyo/ezisilingi) | 4 | 70 W | 280 W | ≈ 1.5 × (injini) |
4 | Ifriji | 1 | 150 W | 150 W | ≈ 3 × = 450 W |
5 | Isikhenkcezisi 6,000 L (umthamo omkhulu, ukusetyenziswa kwezorhwebo) | 1 | 600 W | 600 W | ≈ 3 × = 1,800 W |
6 | Iketile yombane | 1 | 1,800 W | 1,800 W | — |
7 | Impompo yamanzi equleni (engena emanzini / umphezulu) | 1 | 1,100 W | 1,100 W | ≈ 3 - 4 × = 3,300 - 4,400 W |
TOTAL | 4,200 W (4.2 kW) | ≈ 7.5 – 9 kW (ehamba kancinci) |
⚠️ Izinto eziza kuqinisekiswa ngumthengi — amanani amandla eyunithi angentla ngamaxabiso aqhelekileyo emarike, hayi amanqaku e-nameplate. Amaxabiso amathathu abaluleke kakhulu ngala: amandla okwenyani epompo yomthombo (uhlobo, imodeli, isigaba esinye/isigaba sesithathu, ubunzulu bokuntywiliselwa), amandla efriji eyi-6,000 L , kunye namandla eketile . Ukuqinisekisa la manqaku mathathu kuya kugqiba ubungakanani — bona i-§ 10.
Zintathu iintlobo ezahlukeneyo zomthwalo ezihlala zikhona:
Uhlobo lomthwalo | Izixhobo ezichaphazelekayo | Impembelelo yobugcisa |
Imithwalo yokumelana (elula) | Iibhalbhu ezili-10, iketile engama-1,800 W | Akukho miqathango ithile. Iketile yeyona isetyenziswa kakhulu ngokuqhubekayo (1.8 kW). |
Imithwalo ye-Inductive / motor (ebalulekileyo) | Ipompo yomthombo, iifeni ezi-4, iifriji kunye nee-compressor zefriji | Ifuna i -sine wave ecocekileyo . Isiphumo "se-sine wave eguquliweyo" sibangela ubushushu obugqithisileyo, ukudumba kunye nokuwohloka kwenjini ngokukhawuleza. I-EP12000L inika i-sine wave ecocekileyo, i-THD < 3%. |
Imithwalo yokuhamba ngebhayisekile iiyure ezingama-24/7 (ezi zilingana nebhetri) | Ifriji + ifriji engama-6,000 L | Iicompressor zazo aziqhubeki ngokuqhubekayo (umjikelo womsebenzi ≈ 40 - 50% kwimozulu eshushu), kodwa zimisela ukuzimela ebusuku : zizo ezimele ziqhubeke zisebenza xa imveliso yelanga iyeka. |
Uvavanyo | Ukubala | Isiphumo |
Umthwalo oqhubekayo ngaxeshanye | 120 + 150 + 280 + 150 + 600 + 1,800 + 1,100 | 4,200 W |
Umthamo we-EP12000L, i-230 V yesigaba esinye | — | 11,000 VA |
Isigwebo samandla esiqhubekayo | Ii-4,200 W kwi-11,000 W | ✅ 2.6 × umda — akukho mngcipheko wokugqithisa kakhulu, nokuba zonke izixhobo zisebenza ngokusisigxina |
Ukunyuka okuphezulu kwesikhashana (ipompo iqala ngelixa iketile kunye nezixhobo zokupholisa zisebenza) | 4,400 + 1,800 + 600 + 150 + 280 + 150 + 120 | ≈ 7,500 W (ukuya kuthi ga kwi-9 kW ukuba icompressor iqala ngaxeshanye) |
Incopho ye-EP12000L, i-230 V yesigaba esinye | — | 22,000 VA |
Isigwebo sokunyuka | ≈ 9,000 W kwi 22,000 W | ✅ 2.4 × umda — ipompo ingaqala ngaphandle kokusika umbane ukuya kwenye indlu |
Uqikelelo lokusetyenziswa kwemihla ngemihla, kuthathelwa ingqalelo imijikelo yomsebenzi wokwenyani (izixhobo zokupholisa azitsali amandla alinganiselweyo iiyure ezingama-24 ngosuku, iintsuku ezisixhenxe ngeveki; iketile kunye nepompo zihlala zingasebenzi):
Into | Ukubala | Ukusetyenziswa / ngosuku |
Ukukhanyisa (10 × 12 W, iiyure ezili-10 ngokuhlwa) | 120 W × 10 iiyure | 1.2 kWh |
IiTV (2 × 75 W, iiyure ezi-6) | 150 W × iiyure ezi-6 | 0.9 kWh |
Iifeni (4 × 70 W, iiyure ezili-10) | 280 W × iiyure ezili-10 | 2.8 kWh |
Ifriji (150 W, umjikelo womsebenzi we-40%) | 150 W × 24 iiyure × 0.40 | 1.4 kWh |
Isikhenkcezisi see-litre ezingama-6,000 (ii-litre ezingama-600 W, umjikelo womsebenzi ongama-45%) | 600 W × 24 iiyure × 0.45 | 6.5 kWh |
Iketile (1,800 W, imizuzu engama-30 ngosuku) | 1,800 W × 0.5 iiyure | 0.9 kWh |
Impompo yamanzi (1,100 W, iiyure ezi-2 ngosuku) | 1,100 W × iiyure ezi-2 | 2.2 kWh |
TOTAL | ≈ 15.9 kWh/ngosuku |
Isalathiso | Inkcazo | Ubungakanani | Indima |
EP12000L | Isikhululo samandla esiphathwayo — i-inverter edibeneyo yecala eli-2 + ibhetri | 1 | Undoqo wenkqubo: Unikezelo lwe-230 V / 50 Hz + indawo yokugcina + ukutshaja ngelanga |
EP12000B | Ibhetri yolwandiso, 11,776 Wh | 1 | Ukuzimela kabini ukuze kugqunywe usuku lonke |
Uthotho lwe-DSF / DS | Iiphaneli zelanga ≈ 4.6 kWp (umz. 8 × 580 W) | Iseti e-1 | Umthombo oyintloko wokutshaja emini (eSenegal: imitha yelanga ephezulu kakhulu) |
(Umthombo: EP12000 移动电源参数 V1.8 — iphepha leenkcukacha zokugqibela)
Ipharamitha | Ixabiso |
Amandla alinganisiweyo (i-230 V yesigaba esinye) | 11,000 VA |
Amandla aphezulu (isigaba esinye) | 22,000 VA |
I-voltage yemveliso yesigaba esinye | 220 / 230 / 240 V |
Izihlandlo | 50 / 60 Hz → iyahambelana negridi yaseSenegal (230 V / 50 Hz) |
Ifomu ye-waveform yemveliso | I-sine wave ecocekileyo , i-THD < 3% (ibalulekile kwimpompo nakwii-compressors) |
Ibhetri eyakhelwe ngaphakathi (EP12000L) | I-LiFePO₄, 7,680 Wh , 150 Ah (51.2 V), imijikelo engama-3,000 ukuya kumthamo wama-80% |
Ibhetri yolwandiso (EP12000B) | LiFePO₄, 11,776 Wh , 230 Ah (51.2 V) |
Ukukhula | Iibhetri ezifikelela kwi-31 ezinokuhlanganiswa → 372 kWh iyonke |
Ukusebenza ngaxeshanye | Iiyunithi ezi-2 ezipakishwe → ukuya kuthi ga kwi -24 kVA imveliso eqhubekayo (akukho khithi eyongezelelweyo ehambelanayo efunekayo) |
Ukutshaja kwelanga okunamandla aphezulu (isigaba esinye) | 80 – 450 VDC, 2 × 20 A max, 2 × 5,500 W PV, ukuya kuthi ga kwi -7,500 W kwibhetri → ukutshaja okupheleleyo kwimizuzu engama-70 |
Ukutshaja kwelanga okunombane ophantsi | 12 – 150 VDC, ubuninzi be-12,000 W → ukutshaja okupheleleyo kwiiyure ezisi-7 |
Ukutshaja igridi/ijenereyitha | 180 – 250 VAC, 16/32 A ubuninzi, 7,000 W ubuninzi → ukutshaja ngokupheleleyo kwimizuzu engama-70 |
Umsebenzi we-UPS | Ukudluliselwa kwebhetri yegridi ↔ kwi ≤ 10 ms |
Ubushushu bokusebenza | Ukukhupha: −20 °C ukuya kuma-50 °C / Itshaja: 0 °C ukuya kuma-45 °C |
Uvavanyo lokhuseleko | Iyunithi IP43 / Iphakheji yebhetri IP66 |
Iziphumo ze-AC | (10 – 50 A × 4 – 5) + 63 A × 1 (okanye 32 A × 1 ngaxeshanye) |
Iziphumo zeDC / USB | I-XT90 12 V/30 A, isibane sokukhanyisa icuba 12 V/10 A, 2 × 5521 12 V/6 A, 2 × USB, 2 × QC3.0, 2 × Uhlobo-C PD 140 W, 2 × 5 – 15 W yokutshaja ngaphandle kwentambo |
Ukubeka iliso | Iphaneli ye-LCD + usetyenziso lweselfowuni (qala, yima, ujonge iiparameter ngexesha langempela) |
I-Chassis | Iindlela ezineevili ezine kunye neerola ezinkulu zinokutshintshwa nangaliphi na ixesha, izibambo ezidibeneyo, iibhampa zerabha ezijikelezayo |
Iwaranti | Iminyaka emi-5 |
Iziqinisekiso | Iyahambelana nemigangatho yokhuseleko ye-EU kunye ne-US |
Ubukhulu: 840 × 670 × 490 mm — 100 / 110 kg (EP12000L iyunithi ephambili).
Umthamo ongasetyenziswayo uthathwa kwi-90% yesiqhelo (ubunzulu bokukhupha obugcina ubomi benkonzo ye-LiFePO₄).
Imeko | Umthwalo utsaliwe | I-EP12000L yodwa (7,680 Wh) | EP12000L + EP12000B (19,456 Wh) |
A. Yonke into isebenza ngaxeshanye (iketile + ipompo + ukupholisa + izibane + iiTV ezi-2 + iifeni ezi-4) | 4.2 kW | ≈ 1 iyure 40 | ≈ iiyure ezi-4 10 |
B. Ukusetyenziswa ngokuhlwa ngokwenene (ukupholisa ngexesha lomsebenzi + iibhalbhu ezili-10 + iifeni ezi-4 + iiTV ezi-2 + iketile ngamanye amaxesha) | ≈ umyinge we-800 W | ≈ 8 iiyure 40 | ≈ 21 iiyure 30 |
C. Ipholisa kuphela, ubusuku obungenalanga (ifriji + ifriji ye-6,000 L, isebenza ngebhayisekile) | ≈ 330 W umyinge | ≈ iiyure ezingama-21 | ≈ iiyure ezingama-53 (≈ iintsuku ezi-2) |
D. Ukusetyenziswa ngokupheleleyo kwemihla ngemihla (≈ 15.9 kWh/ngosuku, § 2.2) | 15.9 kWh | Iintsuku eziyi-0.4 | ≈ usuku olu-1 olupheleleyo — kunye nokutshaja kwelanga ngaxeshanye emini |
Ngokwenyani: nge-1 × EP12000L + 1 × EP12000B, ukufakelwa kwakho kusebenza iiyure ezingama-24 ngosuku , iintsuku ezisixhenxe ngeveki : emini, i-solar iyayitshaja ibhetri ngelixa ibonelela ngendlu; ebusuku, ibhetri iyayithatha indawo. Ukuba akukho langa kangangeentsuku ezininzi ezilandelelanayo, umsebenzi we-UPS uvumela ukutshaja kwakhona kwigridi (okanye ijenereyitha) kwimizuzu engama-70 kuphela .
Umthombo | Ukufumaneka eSenegal | Ukusebenza | Ingcebiso |
Ilanga (eliphambili) | Imitha ephezulu kakhulu (≈ 5,000 – 5,500 Wh/m²/ngosuku) — phakathi kwezona zibalaseleyo ehlabathini | Ibhetri ifikelela kwi-7,500 W → imizuzu engama-70 (i-voltage ephezulu) | ✅ Umthombo 1 : iindleko zokusebenza eziphantse zibe zero |
Igridi | Ifumaneka kodwa inokuba ingasebenzi/inciphe umthwalo | 7,000 W ubuninzi → 70 min | ✅ Ukutshaja kwakhona, ingakumbi ngexesha lemvula |
Umvelisi wepetroli | Iqhelekile njenge-backup | 7,000 W ubuninzi → 70 min | ✅ Isisombululo esingxamisekileyo (esingabizi kakhulu kunanamhlanje: sisebenza kuphela ukuze sitshaje, kungekhona ukuze sinikeze imithwalo) |
Umoya | Amandla aphantsi ngaphandle kweendawo ezikunxweme | Ukuya kuthi ga kwi-2,000 W | Ukhetho, hayi into ephambili |
Imfuneko | Ukubala | Amandla e-PV acetyiswayo |
Gquma i-100% yokusetyenziswa kwemihla ngemihla (≈ 15.9 kWh) | 15.9 kWh ÷ Iiyure ezi-4.5 zelanga eliluncedo ÷ 0.78 (ukulahleka kwenkqubo) | ≈ 4.6 kWp (umz. 8 × 580 W) |
Gquma ukusetyenziswa okubalulekileyo kuphela (≈ 8 kWh: ukupholisa + izibane + iifeni) | 8 kWh ÷ 4.5 h ÷ 0.78 | ≈ 2.3 kWp (umz. 5 × 450 W) |
I-EP12000L yamkela ukuya kuthi ga kwi-2 × 5,500 W yeepaneli ezine-voltage ephezulu (isigaba esinye): uqwalaselo lwe-4.6 kWp luhambelana ngokuthe ngqo kwaye luhlala lunokwandiswa.
Isekethe | Imithwalo eqhagamshelweyo | Amandla aqhubekekayo | Phawula |
Isekethe 1 — Ukupholisa (okubaluleke kakhulu) | Ifriji + ifriji engama-6,000 L | 750 W (ukunyuka kwe-2,250 W) | Zisebenza ngokusisigxina; ezi mithwalo azinyamezeli kakhulu ukuphazamiseka (itsheyini ebandayo, iimpahla) |
Isekethe yesi-2 — Ipompo yomthombo | Impompo yamanzi | 1,100 W (ukunyuka kwe-4,400 W) | Isekethe ezinikeleyo: ithintela ukunyuka kwepompo ekuphazamiseni ezinye izixhobo |
Isekethe 3 — Ukukhanyisa / intuthuzelo | Iibhalbhu ezili-10 + iifeni ezi-4 + iithelevishini ezi-2 | 550 W | Isekethe esetyenziswa kakhulu ngokuhlwa |
Isekethe 4 — Ikethi | Iketile yombane | 1,800 W | Ukusetyenziswa ngamaxesha athile; kuphephe ukuyivumelanisa ne-pump start-up (i-EP12000L iyayilawula, kodwa oku kuyayigcina ibhetri) |
Ukhetho | Uqwalaselo | Amandla aqhubekekayo | Incopho | Umthamo ogciniweyo | Isigqibo |
A — Icetyisiwe | EP12000L + 1 × EP12000B | 11 kW | 22 kW | 19,456 Wh | ✅ Eyona ifanelekileyo : 2.6 × umda kumthwalo, usuku olupheleleyo lokuzimela, olunokwandiswa |
B — Ezoqoqosho | I-EP12000L yodwa | 11 kW | 22 kW | 7,680 Wh | ✅ Yanele amandla; ukuzimela okungaphelelanga (≈ iiyure ezi-8 xa isetyenziswa ngokwenene) — kufuneka itshajwe imihla ngemihla |
C — Uhlahlo lwabiwo-mali oluphantsi | EP6000LS | 6 kW | 12 kW | 5,376 Wh | ⚠️ Iyasebenza kodwa umda uyehla uye kwi-1.4 × : umsebenzisi kufuneka aphephe ukuqala ipompo ngaxeshanye neketile kunye neecompressor |
D — Ingakhula / isakhiwo sonke | 2 × EP12000L ngaxeshanye | ukuya kuthi ga kwi-24 kVA | — | inokwandiswa ukuya kwi-372 kWh | ✅ Ukwandisa kwixesha elizayo (indawo yokusebenzela, umoya opholileyo, izakhiwo ezongezelelweyo) |
E — Eyongezelelweyo | EP5000iL | 5 kW | 10 kW | 3,430 Wh | ⚠️ Ayonelanga yodwa umthwalo opheleleyo ngaxeshanye; ingasetyenziswa njengeyunithi eyongezelelweyo okanye kwi-subset (izibane + iiTV + iifeni) |
Zombini ezi modeli zinokunika amandla uluhlu lwezixhobo zakho. Umahluko uxhomekeke kwiinkampani eziqalayo ngaxeshanye :
ukuba kuphela u
iketile, ipompo kunye neecompressor zombini aziqali ngaxeshanye. Loo nto yimiqathango yokusetyenziswa ekufuneka ibekwe kumsebenzisi yonke imihla.
kuzo zonke iimeko
, ngaphandle kwemida yokusetyenziswa. Olu lukhetho olucetyiswayo lokufakela apho umsebenzisi kungafanele abeke esweni izixhobo zakhe.
Umda wendawo | Impendulo yobugcisa |
Igridi yesigaba esinye engama-230 V / 50 Hz | I-EP12000L inika i-220/230/240 V kwi-50/60 Hz — iyahambelana ngaphandle kwe-transformer |
Ukucima rhoqo nokucima komthwalo | Umsebenzi we-UPS owakhelwe ngaphakathi: igridi ↔ ukudluliselwa kwebhetri kwi- ≤ 10 ms , ayibonakali kwifriji nakwifriji (akukho kuqhawuka kwikhonkco elibandayo) |
Amaqondo obushushu aphezulu (30 - 45 °C) | Ubushushu bokukhupha bufikelela kwi- 50 °C ; inkqubo yokupholisa enemijelo emibini enelungelo elilodwa lomenzi |
Uthuli lweHarmattan kunye nokufuma konxweme | Iphakheji yebhetriIP66 , iyunithi ye-IP43; izibambo kunye neebhampa zerabha macala onke |
Ukuqalisa injini (ipompo, iicompressor) | I-sine wave ecocekileyo, i-THD < 3% + 22 kW incopho |
Umthombo welanga ongaqhelekanga | Ukutshaja ngelanga ukuya kuthi ga kwi-7,500 W → Ukutshaja okupheleleyo kwemizuzu engama-70 , iindleko zokusebenza eziphantse zibe zero |
Indawo ekude okanye ishishini elikhulayo | Itshasi enamavili amane inokutshintshelwa kwimowudi enamavili amabini, izibambo ezidityanisiweyo: iyunithi ingashukunyiswa, isetyenziswe kwaye yandiswe (ukuya kuthi ga kwi-372 kWh) |
1. Ngaba i-kettle eyi-1,800 W, ipompo kunye nee-compressor zombini zingaqala ngaxeshanye? Ewe. Ukunyuka okudibeneyo kwe-transient kuqikelelwa phakathi kwe-7.5 kunye ne-9 kW, ngaphantsi kakhulu kwe-EP12000L's 22 kW peak. Nge-EP6000LS (12 kW peak), loo nto ngexesha elinye ingaba yingozi.
2. Isebenza ixesha elingakanani ifriji ye-6,000 L ngexesha lokucima? Malunga neeyure ezingama-21 nge-EP12000L yodwa (imo yokupholisa kuphela), kwaye ukuya kuthi ga kwiiyure ezingama-53 ngebhetri yolwandiso lwe-EP12000B. Njengoko udluliselo lwe-UPS luyi-≤ 10 ms, i-compressor ayiqalisi kwaphela: ikhonkco elibandayo aliphazanyiswa.
3. Ingakanani indawo yephaneli yelanga efunekayo? Malunga ne -4.6 kWp (umzekelo iiphaneli ze-8 × 580 W) ukugubungela ukusetyenziswa okuqikelelweyo kwemihla ngemihla kwe-≈ 15.9 kWh. Uhlobo oluncitshisiweyo lwe -2.3 kWp lwanele ukuba ubeka phambili ukupholisa, ukukhanya kunye neefeni.
4. Ngaba inkqubo ingahlala iintsuku ezininzi ngaphandle kwelanga okanye igridi? Nge-1 × EP12000L + 1 × EP12000B, ukuzimela kokusetyenziswa ngokwenene kumalunga neeyure ezingama-21 , kwaye ukuya kuthi ga kwiintsuku ezi-2 kwimodi yokuphola kuphela . Kwiintsuku ezininzi zokuzimela kuyo yonke imithwalo, yongeza nje iibhetri zolwandiso ze-EP12000B (ukuya kuthi ga kwiiyunithi ezingama-31, oko kukuthi, i-372 kWh).
5. Ingaba iyahambelana negridi yaseSenegal? Ewe: imveliso yesigaba esinye 220/230/240 V — 50/60 Hz, kunye ne-AC input 180 – 250 VAC. Akukho mfuneko yeadaptha okanye itransformer.
6. Kwenzeka ntoni kanye kanye xa kukho ukucima? Inkqubo idluliselwa ngokuzenzekelayo ukusuka kwigridi ukuya kwibhetri ngaphantsi kwe-10 ms . Iibhalbhu azidanyazi, iifeni aziyeki, iithelevishini aziqali kwakhona, kwaye iicompressor zokupholisa aziphulukani nomjikelo wazo.
7. Ngaba iibhetri okanye i-inverter yesibini inokongezwa kamva? Ewe. Iibhetri zokwandisa ezifikelela kuma-31 (zizonke ziyi-372 kWh), kunye neeyunithi ezimbini ze-EP12000L ezipakishiweyo zibonelela nge- 24 kVA ngaphandle kwekhithi eyongezelelweyo ehambelanayo.
8. Ingakanani ixesha lokusebenza kwaye loluphi ulondolozo olufunekayo? Ibhetri yeLiFePO₄ ilinganiswe ngemijikelo engama-3,000 ukuya kwi-80% yomthamo, inewaranti yeminyaka emi-5 . Akukho kulungiswa kukhulu: akukho petroli, akukho tshintsho lweoyile, akukho kuqaliswa ngesandla. Ukubeka iliso kwenziwa kwi -app yeselula (imeko yetshaja, umbane, izilumkiso).
Ukuze siguqule esi siphakamiso sibe yimeko yokugqibela kunye nesicatshulwa, kufuneka kuqinisekiswe amaxabiso amathathu:
# | Ulwazi oluza kuqinisekiswa | Kutheni le nto ithatha isigqibo | Indlela yokujonga |
1 | Impompo yamanzi equleni : amandla (W okanye hp), isigaba esinye okanye isigaba sesithathu, esintywiliselwa emanzini okanye umphezulu, ubunzulu | Ngumda wobukhulu ongunombolo 1 (ukunyuka × 3 - 4). Ipompo ye-2.2 kW endaweni ye-1.1 kW ingatyhala ukunyuka ukuya kwi-≈ 9 kW ngokwayo. | Ipleyiti yegama lemoto, okanye ifoto yepleyiti |
2 | Isiqandisi se-6,000 L : amandla e-compressor, i-voltage yokubonelela | Imisela ukusetyenziswa kwemihla ngemihla (eyona nto inzima kwibhalansi yamandla: 6.5 kWh/ngosuku) kwaye ngoko ke ubukhulu belanga | Ipleyiti yegama lesixhobo |
3 | Iketile yombane : amandla okwenyani | Iqala kwi-1,200 ukuya kwi-2,200 W kuxhomekeke kumzekelo | Ipleyiti yegama lesixhobo |
Ulwazi olongezelelweyo oluluncedo:
Iimpawu zemveliso ezicatshulwe kolu xwebhu zivela kumaphepha eenkcukacha zangaphakathi zomenzi:
Uxwebhu lomthombo | I-element esetyenzisiweyo |
EP12000 移动电源参数 V1.8-定稿 | Ukulinganiswa kwamandla, ii-voltage, amandla ebhetri, igalelo lokutshaja, ukulinganiswa kwe-IP, amaqondo obushushu, iziphumo |
EP12000 移动电源介绍 V1.3 | Inkcazo yokusebenza, ukunqwabelana, ukusebenza ngaxeshanye, usetyenziso |
EP12000 移动电源优势 V1.2 | Iingenelo zemveliso (ukupholisa, itshasi, i-UPS, iwaranti, iziqinisekiso) |
EP6000 移动电源参数 V1.5-定稿 / EP6000 移动电源介绍 V1.1 | Iinkcukacha zokhetho lwe-EP6000LS |
EP5000iL 移动电源参数 V1.0 | Iinkcukacha zokhetho lwe-EP5000iL |
DPiL 系列参数汇总 V2.8 / EP3600 / BP3600 / BP2400 参数 | Uthelekiso loluhlu |
Inqaku lendlela yokusebenza: ukulinganiswa kwamandla eyunithi yezixhobo zomthengi (§ 1.1) ziingcamango zemarike ezisetyenziselwa ubungakanani bangaphambili, kungekhona amaxabiso alinganisiweyo. Ubalo lokuzimela lusekelwe kubunzulu obusebenzisekayo bokukhupha obuyi-90% nakwimijikelo yomsebenzi wecompressor eyi-40 - 45%, amaxabiso aqhelekileyo kwimozulu eshushu. Ukuqinisekisa idatha ye-nameplate (§ 10) kuya kugqiba la manani.
Uxwebhu olulungiselelwe liqela lokuthengisa — nawuphi na umbuzo wobugcisa malunga nobungakanani uza kuphendulwa zingadlulanga iiyure ezingama-24.